| We offer a complete range of equipment to carefully nurture the infants in the most hygienic conditions. |
| Photo therapy Unit Double Surface |
| In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the billirubin can permanently damage the brain. This indirect billirubin, which is not water soluble, can be decomposed to a harmless metabolic, which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate. This is achieved by exposing the infant to bright light (app. 4.5 micro watts/sq.cm/nm) in the range of 420 to 480nm wave length. This is used for treatment of Hyperbillirubiaemia in Neonates, which provides the light source in range of 420-480 nm wave length. Double surface Photo therapy Unit is the combination of over head photo therapy unit and under Surface Photo therapy unit. |
| Undersurface Photo therapy Unit |
- Baby Bassinet with fold down panels.
- Head down position, on both sides.
- Photo therapy Unit fitted at a distance of 300 mm from baby bed.
- 4 Blue + 2 white tubes in Overhead Photo therapy Unit Choice of two kinds of tubes for use with
- 4nos of blue light tubes with higher intensity of light in therapeutic range and 2 no's of white light tubes.
- 6 no's. of white light tubes with the facility to use 4 or 6 tubes at a time
- Compact & mobile
|
 |
| Photo therapy Unit Single Surface (Overhead Unit) |
- Overhead Photo therapy Unit Choice of two kinds of tubes for use with
- 4 no's of blue light tubes with higher intensity of light in therapeutic range and 2 no's of white light tubes.
- 6 no's. of white light tubes with the facility to use 4 or 6 tubes at a time
- Facility of height adjustment, so as to fit over an i incubator or baby cot etc.
- Fold up facility during inspection of neonates or storage.
- Angle folding facility, for using along with radiant warmer.
- Compact & mobile
Technical Specification
Power Supply 220V 50Htz, 120/160watts |
 |
| CFL Photo therapy Unit |
- CFL Provides the light intensity of 18 pw/cm2/nm (approx) at 45cm from Baby cot.
- Choise of 6 Blue or 4 Blue + 2 white CFL lamps for treatment and inspection.
- Height 120 cm to 160 cm from the base.
- Head Tilting Facility from-1800 + 1800 (Continuous).
- 3 swivel castors fixed on sleek T-shaped base.
- Powder coated scratch and rust proof body.
- Special mirror Coated Reflector For better reflection.
|
 |
Infant Radiant Warmer
Model:- Tiana IRW 1723
SST Infant Warmers are designed to provide advance warming capabilities while using one touch operations to simplify procedures.
Immediately after delivery the new born baby experiences some degree of thermal instability as it comes from the mothers womb which has the stable environment to the cooler environment of the delivery room.
|
- Available with a choice of thermal control system Skin/Manual control.
- Two function control modes provide the clinician more flexibility while optimizing the thermal environment.
- In addition, the Skin/ Air temperature display is larger then the other set temperature display.
- Advance microprocessor controlled with self-check on the electronic circuit.
- Digital display of patient temperature and soft touch display of control temperature.
- Skin Temperature can be converted from Celsius to Fahrenheit by the push of a button.
- The spacious baby bed incorporates easily drop down sides for maximum access to the patient.
- The control panel is also the heart for a completely integrated alarm system with both audible and visual indicators in the event of
- Probe Fail.
- Skin High.
- Skin Low.
- Power Fail.
- Heater Fail.
|
 |
Manual Mode
- Facility to converting the warmer from servo mode to manual mode for non-stop working.
- In Manual mode warmer will start from 40% heat and can be increased up to 99% according to usage
Heater Assembly
- The Heater assembly located above the center of the support structure consists of radiant heater and reflector with inbuilt halogen examination lamp for assessment of Infant Color.
Technical Specification
|
| Height |
1850mm |
| Length |
900mm |
| Width |
700mm |
|
| Electrical Specification |
| Height |
1850mm |
| Length |
900mm |
| Width |
700mm |
|
Open Care System (Model:TIANA)
Microprocessor Controlled |
- The digital, microprocessor-based controller comes standard with a full spectrum of features.
- The Tiana Open care system comes complete with automatic Manual and baby (Servo) modes.
- Two function control models provide the clinician more flexibility while optimizing the thermal environment.
- Skin temperature display is larger then other set temperature display
- Skin temperature display can be converted from °C to °F by the push of a button.
- A full complement of alarm provides safety and convenience, with both audible and visual indicators in the event of:
High Temp. / Low Temp.
Set High / Set Low
Probe Failure
Power Failure
|
- The system automatically starts the heating from 40% in manual mode and the same can be changed through settings up to 99%.
- The High & Low Temp. alarm settings can be adjusted according to the patient condition.
- The Radiant Warmer Features an independent ambient temperature probe which maximizes the heating efficiency across the range of operating temperature.
- A big LCD is provided for more specific information & visualization of the heater power in manual and servo modes.
- The system automatically converts from servo mode to manual mode in case of probe failure thus providing non stop working of the unit.
- The spacious baby bed incorporates easily drop down sided for maximum access to the patient.
|
 |
Heater Assembly
The heater assembly located above the center of the support structure consists of an integral examination light and a 650 Watts heating system for quick warming and even distribution of heat on the baby bed.
The First Breath
- The open care system combines virtually all the technology a caregiver may need in situation needed for resuscitation.
- The neonate can be supplied with a constant oxygen flow through the Oxygen humidifier when connected to an oxygen cylinder (optional).
- The motorized slow suction can be used with a simple flip of a switch
- A digital Apgar timer is standard, which signals when 1,5 and 10 minutes have elapsed
|
 |
| Technical Specification |
| Height |
1924mm |
| Length |
884mm |
| Width |
858mm |
|
| Electrical Specification |
| Power supply |
200V/50Htz |
| Heater Power |
650Watts |
| Fuse |
5 Amp |
| IEC |
COMPLIANT |
|
| 1 2 |